Incorporating the many advantages of the multifunctional T-Port valve, together with a unique and innovative safe method for loading & unloading pigs. This execution is also equipped with an integrated pig changing chamber and pig propellant connections. In addition to the standard two automated valve positions there is also a third manual valve position for changing pigs. The pig changing procedure requires no external utility services, or control system action. The orientation of the pig changing chamber ensures that the pigging line is isolated when changing pigs, providing the highest levels of operator safety.
T40.29 - T-Port Valve as Launching station: New safety standards for pig changing procedure
- As Launching station equipped with integrated pig changing chamber, separated from the pigging line
- Pig isolated from Product Flow
- Safe Pig changing facility, without external Energy/Utility Services, or Control System action
- Compact size
- Cost effective
Connections | Flange DIN DN 50 to DN 100 in PN 16 or. ANSI 2" - 4" 150 lbs. (other types on request) |
---|---|
Nominal Pressure | PN 16 / 150 lbs (up to 80°C), PN 25 / 300 lbs on request. |
Operation | Pneumatic double acting or manual. Pig changing manual |
Design Temperature | -15°C to max. +120°C |
Operating Temperature | -20°C to +75°C (for higher temperatures an alternative actuator will be necessary) |
Material | Housing: Stainless steel 1.4571 or Carbon steel 1.0570; Sealings: NBR, FKM, VMQ or EPDM |